Published
Start with the test method
Hydrostatic head is a measure of resistance to water penetration under pressure. Ask each supplier for the method and edition, the pressure increase rate where applicable, the surface exposed to water and the endpoint used to record a result. A value in millimetres of water can be expressed in other pressure units, but converting units cannot make different test procedures comparable.
Compare specimens in the same condition
Request the fabric code, construction, finish, colour or lot identifier, and whether the specimens were tested as received or after care. If the order requires testing after laundering, define the washing and drying procedure and number of cycles before sending samples. Compare unwashed results with unwashed results and compare post-care results only when the care procedure matches.
Write the bulk release rule before testing
For an RFQ, state the applicable method and edition, required minimum, test condition, sampling plan and how individual readings are judged. Ask for individual results and the agreed summary. Decide whether each specimen must meet the minimum or whether the contract uses a lot statistic. If a report lacks a method or shows a different condition, request the missing evidence or a retest before using it to release the lot.
Keep fabric, seam and garment evidence separate
A fabric result is useful for shortlisting a shell material. Finished seams, closures and the garment need their own checks under the applicable project requirements. Specify those checks separately, including whether sealed seams must be assessed after care.
References and next steps
- ISO 811:2018 scope and edition. ISO 811:2018 describes a hydrostatic pressure method for assessing fabric resistance to water penetration. Use the method specified for your contract.
- PX22 / RTGEN4 fabric specification. TEC lists a hydrostatic pressure value of 15,000 mm for this fabric. Ask for the test report and conditions before using the listed value as a purchase acceptance criterion.
- TEC sampling and quality checks. Use the quality checklist to agree evidence, production sampling and release responsibilities.